EZ Digital OS-3060D Instructions d'exploitation Page 9

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 8
8
To replace the fuse safely, isolate the appliance
from all voltage sources (pull out the mains
plug!) and voltage circuits. After isolating the
appliance, use a suitable screwdriver to prise
out the fuse holder together with the faulty
fuse fitted, remove the faulty fuse and re-
place it by a fuse of the same type.
When inserting the replacement fuse into the
fuse holder, make sure that the arrow mark
corresponds to selecting the correct mains
input voltage.
10. Exercise special care when dealing with
voltages in excess of 25 V alternating current
(AC) or 35 V direct current (DC). Even at
voltages as low as these, it is still possible to
suffer a life-threatening electric shock if
contact is made with conducting parts.
2. Operating Instructions for Oscilloscope
OS-3020 D/OS-3060 D
3
21 522
23
31
21 20 24
25
28
29 26 27
30
32
11
9
1315173618161214810354
+
TRACE
ROTATION
POWER
ON
INTEN
VOLTS/DIV POSITION
MODE
.1.2
.5
1
.5
.2
50
10
20
5
mV
CAL
CAL
.1.2
.5
1
.5
.2
50
10
20
5
mV
CAL
CH1
CH2
DUAL
ADD
PULL INV
! !
TRIGGER
FOCUS
PROBE
ADJUST
VERTICAL
CH1 X
CH2 Y
AC
DC
GND
VARIABLE
PULL x 5 MAG
HOLD
OFF
LEVEL
MODE SOURCE
AUTO
NORM
TV-V
TV-H
CH1
CH2
LINE
EXT
1 M 25 pF
250 V
MAX
VOLTS/DIVPOSITION Y
IN
OUT
1 M 25 pF
250 V
MAX
DIGITALE STORAGE OSCILLOSCOPE OS-3060 D
60 MHz
OFF
0
+-
POSITION X
VARIABLE
DLYD POSITION
,5 Vpp
SCALE
B TIME/DIV
A TIME/DIV
2
1
.5
.2
µs
20
10
5
EXT TRIG IN
!
HORIZONTAL
STORAGE MODE
STORAGE MENU HOLD
SAVE
PULL x10 MAG
NORM
1 M 25 pF
250 V
MAX
VARIABLE
PULL x 5 MAG
x100 WHEN ROLL
S
.2
.1
50
10
20
5
2
1
.5.
ms
.2.
.1
.50
20
10
µS
5
2
1
.5
.2
.1
READOUT/CURSOR HORIZ DISP
SINGLE SELECT PLOT
RECALL
A
B
X-Y B TRIG'D
A INT
V.
ON/OFF SELECT
AC
DC
GND
T.1/ TV.
T.1/ T
2.1 Description of controls
Fig. 2, Front view
11. Before each measurement, check your mea-
suring appliance (oscilloscope) and mea-
suring leads (probes, BNC cable) and the
power cord for damage.
12. To avoid any possibility of electric shock,
ensure that you do not come into contact,
even indirectly, with the probe tip(s) and/or
alligator clips in the case of exposed BNC
wiring or the connections being measured
(measuring points).
13. When safe operation is obviously no longer
possible, the appliance must be taken out of
use and secured from being accidentally
switched on.
It can be assumed that safe operation is no
longer possible when:
- there is visible damage to the appliance,
- the appliance is no longer working,
- the appliance has been stored for an ex-
tended period in unsuitable conditions,
- it has been exposed to adverse transport
conditions.
Vue de la page 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 43 44

Commentaires sur ces manuels

Pas de commentaire